Service Hotline: 4000-888-699
   
Product center Products
Products
发布时间: 2018 - 04 - 11
Technical features:1. Wide voltage range inputPower voltage: -15% - 10%, 47 Hz - 63 Hz; provided with under-voltage underclocking output function that extends the applicable range of power voltage to -30% (e.g. extending the applicable range of a 380 V VFD to 266 V - 440 V); 2. High disturbance resistance Pulse group tests: ± 4,800 VStatic (air discharge): 8,000 VStatic (contact discharge): 6,000 VProvided with EMI circuit + lightning protection design3. Phase-phase and phase-to-earth short circuit protectionAny phase-phase short circuit protection 4. Anti-corrosion treatment8 µm nickel plating, and three layers of British conformal coating for key parts;5. Power source of control signals:  External power supply of +10 V and +24 V, both provided with shor...
发布时间: 2015 - 09 - 16
Technical features> Provided with an open-loop vector control permanent magnet synchronous motor, easy to wire and highly accurate in revs control, reducing on-site faults; > High dynamic responses, rapidly responding to the given value of speed while guaranteeing the stability of output revs, which allows the system to catch up with the load changes timely, thus increasing the operation efficiency of the system;> Premium overcurrent and overvoltage resistance;> The oscilloscope function of the background monitoring software monitors the real-time operation status of the VFDs for on-site commissioning;> Parameter copying function of the keyboard;> The PWM overmodulation improves the utilization of busbar voltage and increases the output voltage of VFDs, hence is applicable to cases in...
发布时间: 2015 - 05 - 20
Technical features          1. So compact with a width, height and depth of 8.6 cm, 14.5 cm and 12 cm respectively only;       2. The panel supports external access that allow copying of parameters;       3. The standard RS485 interface constitutes an independent VFD network, making it possible to set the VFD as a master or slave for master-slave control;       4. Impulse/analog input and output channels;       5. 16 segments of speed control;       6. Multiple setting channels for running frequency/commands;       7. Provided with output terminals for disconnecting relays,...
发布时间: 2015 - 07 - 14
Technical features Unique suitability to applications that require waterproofing and dust-proofing or that are of serious pollution;> Unique metal enclosure for perfect heat dissipation;> Employing advanced surface powder coating process to provide select color and an elegant appearance;> Phosphorized metal plates provide good anti-rust and -corrosion performance;> Provided with IP54 fans for steady and reliable performance;> Input voltage: 3 AC 380 V ± 15%;> Input frequency: 47 - 63 Hz; power factor: ≥95%;> Control methods: Non-PG vector control and V/F control, where for V/F control, three profiles, i.e. straight line, polyline and multiple power, are available; > Running commands source: given through panels, terminals and RS485 communication;> Frequency giving source: given t...
发布时间: 2015 - 05 - 20
Technical features> Fast response and high starting torque: for better vibration control on starting;> Low torque ripple for more stable running;> Compact structure design and optional built-in braking units (for 30 kW and lower, braking units of standard configuration);> High overload resistance (3 s for 200% of rated loads). Perfect overvoltage suppression when applied in a punching machine;> Smart commissioning: smart setting of V/F profile that doesn’t need professionals for complex commissioning, saving manpower and time;> Compatible with synchronous motors: significantly conserves energy if combined with synchronous motors. Consumes the least power in case of equivalent unit torque;> Convenient human–machine interaction, real-time monitoring of key parameters, and LED + LCD dual-disp...
发布时间: 2015 - 05 - 20
Technical features       1.2.1 Employs high-performance current vector control, making it possible for induction motors to start with high torque.       V/F control:      1 Hz 150% torque (speed regulation range 60:1)      Open-loop vector control:  0.5 Hz 150% torque (speed regulation range 100:1)       Closed-loop vector control:  0 Hz 180% torque (speed regulation range 1,000:1)1.2.2 Various parameter adjustment modes  Static self-adjustment: best suitable to the commissioning where motors are connected with handling machines;  Rotating self-adjustment: best suitable applications where...
发布时间: 2015 - 04 - 16
Technical parametersInstructions of keyboard indicator lamps Indicator lampsNameMeaningUnit indicationHzFrequency indicator lampThe unit of currently displayed parameter is Hz (Hertz).ACurrent indicator lampThe unit of currently displayed parameter is A (Ampere).VVoltage indicator lampThe unit of currently displayed parameter is V (volt).Hz + ARevs indicator lampThe unit of currently displayed parameter is R/MIN (revolution/min).A + VPercentage indicator lampsThe unit of currently displayed parameter is % (percent).Hz + VMPa indicator lampsThe unit of currently displayed parameter is MPa (mega Pascal).Status indication(MON)Indicator lamps of command sourceOff: controlled through the keyboard.  On: controlled through the terminals.  Flashing: controlled through...
发布时间: 2015 - 05 - 20
Technical features  1. Usable under large grid fluctuation;  2. Provided with protection functions such as short circuit, low voltage, overvoltage, quick-acting fuses, overheating, etc.;  3. The braking IGBTs are ensured to work within the saturation zone.  Technical parametersModel:   CDBU300-XXXA-4 seriesFor VFDsAC power supply380 VPower0.75 kW - aboveOutput featuresMax. braking currentRefer to particular models.Activated voltage of braking690 V ± 10 VHysteretic voltage670 V ± 10 VPower supplyU (p+_p-)350 V - 800 VProtectionElectronic thermal relaysIn case of the temperature of cooling fins of the braking unit exceeds 85 °C, the protection is activated, the braking unit stops braking, and the malfunction indicator lamp ligh...
发布时间: 2015 - 04 - 09
Technical features     1.  Proprietary kernel encryption          • Proprietary new PLC encryption, eradicating any possibility of cracking.          • Multiple password protection, protecting users’ programs from malicious cracking.     2.  High-speed input          • 6 channels of high-speed counter, 2 channels 200 k + 4 channels 10 k.          • 2 channels of AB phase signal input, multiple settings.          • Built-in 32-digit high-speed comparators.          • Starts when co...
Products Product Details

CDBU300 series dynamic braking units

Product parameters:
The CDBU300 series dynamic braking units employ the IGBT module as their master device. They are widely used in various VFD systems since they are compact and convenience and can be used in parallel. In case of rapid deceleration and down operation of motors controlled by a VFD, the kinetic energy will be converted into electric energy due to the load inertia and stored on the DC busbar, activating the overvoltage protection or giving rise to failures of the VFD. The braking unit, however, automatically detects the voltage of the DC busbar and switches itself on and off to release such regenerated electric energy to the braking resistor, so that the VFD may control the motor steadily under varying operation conditions.
Scope of application:
Suitable to elevators, centrifugal fans, industrial laundry machines, wire drawing machines, oil pumping units, roller beds, proportional linkwork systems etc., in which great inertia loads exist.
Time to market: 2018 - 04 - 11
Product description:
Model recommendationsNo.Specifications and models (380 V class)Max. braking current1CDBU300-020A-420 A2CDBU300-060A-460 A3CDBU300-080A-480 A4CDBU300-150A-4150 A5CDBU300-350A-4350 ASpecification selection of braking units and resistorsModels of braking units VFD powerRecommended power for braking resistorsRecommended resistance for braking resistorsCDBU300-020A-418.5 kW1.3 kW≥ 35 ΩCDBU300-020A-422 kW1.5 kW≥ 35 ΩCDBU300-060A-430 kW2.5 kW≥ 25 ΩCDBU300-060A-437 kW3.7 kW≥ 20 ΩCDBU300-060A-445 kW4.5 kW≥ 15 ΩCDBU300-080A-455 kW5.5 kW≥ 10 ΩCDBU300-150A-475 kW7.5 kW≥ 8 ΩCDBU300-150A-490 kW14 kW≥ 8 ΩCDBU300-150A-4110 kW14 kW≥ 5 ΩCDBU300-150A-4132 kW14 kW≥5ΩCDBU300-150A-4160 kW14 kW≥ 5 ΩCDBU300-150A-4185 kW14 kW≥ 5 ΩCDBU300-350A-4200 kW20 kW≥3.5ΩCDBU300-350A-4220 kW20 kW≥ 2.5ΩCDBU300-350A-4250 k...
Product manual:
Technical features  1. Usable under large grid fluctuation;  2. Provided with protection functions such as short circuit, low voltage, overvoltage, quick-acting fuses, overheating, etc.;  3. The braking IGBTs are ensured to work within the saturation zone.  Technical parametersModel:   CDBU300-XXXA-4 seriesFor VFDsAC power supply380 VPower0.75 kW - aboveOutput featuresMax. braking currentRefer to particular models.Activated voltage of braking690 V ± 10 VHysteretic voltage670 V ± 10 VPower supplyU (p+_p-)350 V - 800 VProtectionElectronic thermal relaysIn case of the temperature of cooling fins of the braking unit exceeds 85 °C, the protection is activated, the braking unit stops braking, and the malfunction indicator lamp ligh...
  • Features
  • Description
  • Installation video
  • Success case
  • Related Products

Technical features
  1. Usable under large grid fluctuation;
  2. Provided with protection functions such as short circuit, low voltage, overvoltage, quick-acting fuses, overheating, etc.;
  3. The braking IGBTs are ensured to work within the saturation zone.

 

 

Technical parameters

Model:   CDBU300-XXXA-4 series

For VFDs

AC power supply

380 V

Power

0.75 kW - above

Output features

Max. braking current

Refer to particular models.

Activated voltage of braking

690 V ± 10 V

Hysteretic voltage

670 V ± 10 V

Power supply

U (p+_p-)

350 V - 800 V

Protection

Electronic thermal relays

In case of the temperature of cooling fins of the braking unit exceeds 85 °C, the protection is activated, the braking unit stops braking, and the malfunction indicator lamp lights up.

Power indication

In case of an input voltage over 200 V, the indicator lamp of power supply lights up.

Braking indication

When the braking unit is activated, the braking indicator lamp lights up.

Control method

Single unit mode

When a braking unit is activated, the master mode is selected.

Master-slave mode

When multiple braking units operate in parallel, one of them will run in master mode, and the rest, slave mode.

Notes: When more than one braking unit are used in parallel, please make sure that one of them is in master control while the others in slave control, where all parallel braking units are connected or disconnected at the same time, otherwise the braking units will be overloaded and damaged.


Model recommendations

 CDBU300 series dynamic braking units CDBU300 series dynamic braking units

No.

Specifications and models (380 V class)

Max. braking current

1

CDBU300-020A-4

20 A

2

CDBU300-060A-4

60 A

3

CDBU300-080A-4

80 A

4

CDBU300-150A-4

150 A

5

CDBU300-350A-4

350 A

Specification selection of braking units and resistors

Models of braking units

 VFD power

Recommended power for braking resistors

Recommended resistance for braking resistors

CDBU300-020A-4

18.5 kW

1.3 kW

≥ 35 Ω

CDBU300-020A-4

22 kW

1.5 kW

≥ 35 Ω

CDBU300-060A-4

30 kW

2.5 kW

≥ 25 Ω

CDBU300-060A-4

37 kW

3.7 kW

≥ 20 Ω

CDBU300-060A-4

45 kW

4.5 kW

≥ 15 Ω

CDBU300-080A-4

55 kW

5.5 kW

≥ 10 Ω

CDBU300-150A-4

75 kW

7.5 kW

≥ 8 Ω

CDBU300-150A-4

90 kW

14 kW

≥ 8 Ω

CDBU300-150A-4

110 kW

14 kW

≥ 5 Ω

CDBU300-150A-4

132 kW

14 kW

≥5Ω

CDBU300-150A-4

160 kW

14 kW

≥ 5 Ω

CDBU300-150A-4

185 kW

14 kW

≥ 5 Ω

CDBU300-350A-4

200 kW

20 kW

≥3.5Ω

CDBU300-350A-4

220 kW

20 kW

≥ 2.5Ω

CDBU300-350A-4

250 kW

28 kW

≥ 2.5Ω

CDBU300-350A-4

280 kW

28 kW

≥ 2 .5Ω

CDBU300-350A-4

315 kW

35 kW

≥ 2.Ω

CDBU300-350A-4

355 kW

35 kW

≥ 2 Ω

CDBU300-350A-4

400 kW

35 kW

≥ 2 Ω

CDBU300-350A-4*2

450 kW

2 × 28 kW

≥ 2 × 2.5Ω

CDBU300-350A-4*2

500 kW

2 × 28 kW

≥2 × 2.5 Ω

CDBU300-350A-4*2

560 kW

2 × 28 kW

≥ 2 × 2.5 Ω


Overall and installation dimensions

Simple braking units under 80 A

 CDBU300 series dynamic braking units


Braking units of 150 A - 350 A

 CDBU300 series dynamic braking units


发布时间: 2015 - 05 - 20
Technical features  1. Usable under large grid fluctuation;  2. Provided with protection functions such as short circuit, low voltage, overvoltage, quick-acting fuses, overheating, etc.;  3. The braking IGBTs are ensured to work within the saturation zone.  Technical parametersModel:   CDBU300-XXXA-4 seriesFor VFDsAC power supply380 VPower0.75 kW - aboveOutput featuresMax. braking currentRefer to particular models.Activated voltage of braking690 V ± 10 VHysteretic voltage670 V ± 10 VPower supplyU (p+_p-)350 V - 800 VProtectionElectronic thermal relaysIn case of the temperature of cooling fins of the braking unit exceeds 85 °C, the protection is activated, the braking unit stops braking, and the malfunction indicator lamp ligh...
Copyright ©2018 - 2023 Shenzhen Canworld Electrical Technology Co., Ltd 
Rhino Cloud provides enterprise cloud services
Address: China · Shenzhen · Baoan Central District · 3rd Floor, Building 15, F518 Fashion and Creative Park, Baoyuan Road
National unified customer service phone:
4000-888-699